Installation and use of Yadeke 4V210 solenoid valve
Installation and use of Yadeke 4V210 solenoid valve
div>1. Before use, please check whether the components are damaged during transportation, and then install and use them;
2. When installing, please pay attention to the direction of gas flow and whether the connection thread shape is correct. The media used must be filtered through a 40um filter element;
3. Please pay attention to whether the installation conditions meet the technical requirements (such as "voltage", "action frequency", "working pressure", "usage temperature range"
etc.), then install and use;
4. Pay attention to the direction of gas flow during installation. P is the air inlet and A (B) is the working port. , R(S) is the exhaust port;
5. Try to avoid using it in a vibrating environment, and pay attention to anti-freezing measures at low temperatures;
6. When connecting pipelines, Be careful not to wrap the anti-leak tape beyond the end face of the joint, and be careful to remove dust, iron filings and other dirt in the pipe joints to prevent impurities or foreign matter from entering the valve. Inside the body;
7. Please pay attention to dust prevention. It is recommended to install a muffler or silencer throttle valve at the exhaust port. When it is removed and not in use, dustproof boots should be installed on the air inlet and outlet.
8. When debugging the whole machine, it is recommended to use a manual device to debug it first, and then turn on the power for debugging.