Yadeke solenoid valve selection basis


Yadeke solenoid valve selection basis:
1. Select the solenoid valve according to the pipeline parameters: diameter specification (i.e. DN) and interface mode
1) Determine the diameter (DN) size according to the on-site pipeline inner diameter size or flow requirements;
2) Interface method, generally >DN50 requires flange interface, and ≤DN50 can be freely selected according to user needs.
2. Select the solenoid valve according to the fluid parameters: material, temperature group
1) Corrosive fluid: corrosion-resistant solenoid valve and all stainless steel are suitable;edible ultra-clean fluid: suitable Use food-grade stainless steel solenoid valves;
2) High-temperature fluids: Choose solenoid valves made of high-temperature resistant electrical materials and sealing materials, and choose piston-type structures;
< div>3) Fluid state: ranging from gaseous, liquid or mixed state, especially when the diameter is larger than DN25, it must be distinguished;
4) Fluid viscosity: usually below 50cSt, you can choose arbitrarily. If this value is exceeded, a high viscosity solenoid valve must be used.

Previous:Airtac solenoid valve performance descriptionNext:Airtac solenoid valve principle and structural varieties
Contact us|Comments suggestions|Customer contact|User guide
About us|Delivery |Payment |help|After-sales
Hotline:+86 4008-292-877|Telephone:+86 0577-61786628|Fax:+86 0577-61786629|Mobile:+86 158 5777 7578|Email:2227202078@qq.com
© 2010 - 2025 snway.cc All Rights Reserved.
Yueqing Shenwei Pneumatic Co., Ltd.

WhatsApp: +8615857777578Shenwei Pneumatic
HomeCSDCartMy
Loading...
×