Many customers have asked our Sunway customer service about these questions about the principle, dimensional drawing, coil wiring and action diagram of the 4V210-08 solenoid valve. Now the editor of Sunway has sorted it out Relevant information is presented to everyone, hoping to be helpful to those who want to understand these issues. Let me give you a picture firstA physical picture of the 4V210-08 solenoid valve: span>



This picture introduces the 4V210-08 solenoid valve product picture











1. The action diagram of 4V210-08 solenoid valve is as follows:



This picture introduces the 4V210-08 solenoid valve action diagram






2. Working principle of 4V210-08 solenoid valve:

1.4V210-08 solenoid valve is a two-position five-way, single electric control type

2. Two positions refer to two working positions.

3. Five pass refers to one air inlet, two working ports, and two exhausts mouth.

4. When the air inlet is in the initial state, the air inlet P is connected to the working port A, and port A is in the working state at this time.

5. After the power signal is given, the coil is energized and the solenoid valve changes direction. At this time, port P is connected to port B, and port A is exhausted.

6. Generally, solenoid valves are used to control cylinders or divide air circuits, and single electric controls rely on spring return.

7. The dual electronic control does not have an automatic reset function, while the three-position five-way is dual-electronic controlled;its principle is similar to that of the two-position five-way, except that when the air stops (There is no air pressure at the air inlet), it is in the middle position, and there are generally three options to choose from (center sealing, medium pressure, and center leakage)



3. Dimensional drawing of 4V210-08 solenoid valve:


This picture introduces It is the installation dimension diagram of 4V210-08 solenoid valve







4. 4V210-08 solenoid valve coil wiring, as shown in Figure (1):



This picture introduces It is 4V210-08 solenoid valve coil wiring diagram





1. Solenoid valve wiring generally works by connecting two wires. Many users buy solenoid valves but they don’t know how to wire them. What should they do? First, disassemble the junction box. After the junction box is opened, there are white + and - signs inside. The + sign is the positive pole and the - sign is the negative pole. If you follow these signs, you will not go wrong.

2. Some users have three wiring connections on the solenoid valve, so how to connect this wiring method? Explanation: The red and black wires connected to the coil seat type are power wires, and the other wire is a ground wire, which is connected to the solenoid valve shell to prevent leakage of the solenoid valve and serve as a safety protection;the plug-type junction box has three terminals, and the side-by-side terminals are the power supply Wiring, regardless of positive or negative, an independent terminal is the ground wire.



Have said so much4V210-08 solenoid valve Knowledge, don’t you understand a lot! If you have any other questions, you can ask our Shenwei customer service, we will answer you at any time.
Previous:Several important parameter diagrams for cylinder model and size selectionNext:What is the general service life of YATACO solenoid valves, and how many years can it be used?
Contact us|Comments suggestions|Customer contact|User guide